Piping Learning System

The water supply and drainage object model is designed with a stainless steel frame as a whole. The main water supply and drainage piping equipment is installed on the steel frame base and has the characteristics of an open mode. It consists of a domestic water supply system, a fire water supply system, a drainage system and a control system.

Category:
Brands:

Description

Piping Learning System composition

The water supply and drainage object model is designed with a stainless steel frame as a whole. The main water supply and drainage piping equipment is installed on the steel frame base and has the characteristics of an open mode. It consists of a domestic water supply system, a fire water supply system, a drainage system and a control system.

The domestic water supply system mainly consists of a water supply tank, a water supply pump, a water supply pipeline, a pressure transmitter, a pulse water meter, a faucet and a shower head. The pipeline is designed with stainless steel composite pipes, which can be used for cutting, installation and water test operations of stainless steel composite pipes. Through the control system, the variable frequency and constant pressure water supply function of the domestic water supply system can be realized, and the single pump frequency conversion control or double pump switching control can be realized. Function; water consumption can be measured by pulse water meter.

The fire water supply system mainly consists of water supply tank, sprinkler pump, air pressure tank, wet alarm valve, fire alarm controller (linkage type), pressure switch, water flow indicator, fire water supply pipeline, closed sprinkler head, etc. The pipeline is designed with galvanized pipes, which can be used for cutting, threading, installation and water test operations of galvanized pipes. The sprinkler and fire extinguishing function can be realized through the control system.

The drainage system mainly consists of sewage tank, liquid level sensor, drainage valve, drainage pipe and water treatment unit. The drainage pipeline is mainly designed with UPVC pipes, which can be used for cutting, bonding, installation and water test operations of UPVC pipes. Combined with the control system, it can realize the water level detection of the sewage tank and the start and stop control of the drainage pump.

The water supply and drainage automatic control system mainly includes electrical control cabinets, touch screens, operating switches, working status indicators, PLC controllers, inverters, low-voltage electrical, water pumps, water meters, sensors (float level gauges, pressure switches, water flow indicators) , Signal butterfly valve, pressure transmitter), configuration monitoring software, etc. The automatic control function of the water supply and drainage system can be realized through the control system.

Occupational ability that can be inspected through the implementation of project tasks

 

1. System as-built drawing and control electrical schematic drawing;

2. Pipe processing and connection

Cutting, threading, welding and connection of galvanized pipe, stainless steel composite pipe, PPR pipe, UPVC pipe

3. Installation of accessories and devices

(1). Complete the installation of pipe fittings in the domestic water supply system, fire water supply system, water supply system and drainage system;

(2). Complete the installation of water pumps, pressure transmitters, water meters, level gauges, signal butterfly valves, wet alarm valve groups, water flow indicators, closed sprinklers, terminal water testing devices, faucets, showers and other plumbing components.

4. Pipeline pressure test and water flow test

5. Electrical, installation and wiring

Installation and wiring of water pumps, power distribution cabinets, controllers, command components, and operating components.

6. Control program design and debugging

(1). Frequency conversion control program design and debugging

(2). Sprinkler control program design

(3). Meter reading and billing program design

(4). Design of water supply and drainage monitoring program

(5). Configuration monitoring system design

7. Fire alarm controller (linkage type) debugging

(1). System equipment recognition and wiring operation

(2). Installation and connection of alarm controller

(3). Installation and connection of short-circuit isolator

1. Power supply: three-phase four-wire system AC380V±10% 50HZ;

2. Overall dimensions of water supply and drainage model: 2m×0.8m×1.9m (length×width×height); overall dimensions of electrical control cabinet: 0.55m×0.27m×0.8m (length×width×height);

3. Material of water supply and drainage model: stainless steel;

4. Power consumption of the whole machine: <2.5KVA

5. Casters with brakes are installed at the bottom of the device to facilitate the movement and fixation of the device;

6. Safety protection measures: with grounding protection, leakage and overload protection, and misoperation protection functions; safety meets relevant national standards, and all materials meet environmental protection standards.